site stats

Elvis function generator

WebUse the NI Elvis Function Generator to produce a sinusoidal voltage for AC circuits. 2. Use the NI Elvis Oscilloscope to measure the amplitude and phase of amplified sinusoidal … WebA variety of concepts and skills developed in the digital electronics lab series will be combined to design and build a digital clock in a project-based application lab. Students will have the option to build a 12-hour or 24-hour clock which will involve using counters, encoders, flip flops and a other concepts previously learned. Students will also use the …

NI Elvis III: Pattern Generator in LabVIEW

WebWith its hands-on approach, educators can help students learn practical, experimental skills. NI ELVIS II features one compact form factor integrated with 12 of the most commonly used instruments in the laboratory, including an oscilloscope, digital multimeter, function generator, variable power supply, and Bode analyzer. You can connect the PC ... WebMake sure to adjust the function generator DC offset to raise and lower the average value of each time-varying voltage, and observe the effects on the oscilloscope screen. For each of the following functions calculate the theoretical RMS voltage using the formula 𝑉 𝑝𝑝 √2 and write down the actual RMS voltage found on the Oscilloscope. flink kafka source exactly-once https://clickvic.org

6. Free Space Optical Communication Link — elec2210 1.0 …

WebNov 3, 2024 · Build the low-pass filter circuit mentioned above on the breadboard. If you do not know how the breadboard a circuit, you can view the How to Breadboard with NI ELVIS III tutorial. Connect to the Instruments. Connect a probe to the Function Generator CH 1. Connect two more probes, one to the Oscilloscope Ch1, and the other to CH 2. WebChebyshev Filter - Construct the second-order Sallen-Key low-pass active-filter circuit shown below. - Use the NI ELVIS function generator and oscilloscope to observe its frequency response. - Complete the table below, measuring frequency response between 10 Hz up to 20 kHzz - Once completed, use Microsoft Excel to create a Bode plot. Find out ... WebUse the NI Elvis Function Generator to produce a sinusoidal voltage for AC circuits. 2. Use the NI Elvis Oscilloscope to measure the amplitude and phase of amplified sinusoidal signals for AC circuit analysis. 3. The student will analyze, build, and test several op-amp circuits in order to develop fundamental understanding of how op-amps work ... greater hartford community college

Solved: NI-mydaq "Drawing too much power" - NI Community

Category:Using myDAQ with the NI ELVISmx Function Generator Soft Front Panel …

Tags:Elvis function generator

Elvis function generator

Using Multisim Live with NI ELVIS III - NI

WebPlease go over Table 1-2 for a description of the functionality of NI ELVIS function blocks contained in the SIGEx board. 3. Identify the location of each circuit module and function block in the actual board and create ... GENERATOR or FUNCTION GENERATOR/SYNC outputs. The state of the DIP switches at any time is displayed on the SIGEx SFP ...

Elvis function generator

Did you know?

WebAug 18, 2024 · The NI ELVIS II prototyping board is an incredibly useful tool to test your circuits before you go through all the work of soldering. Here is how to use some of its basic functions. ... If you need to generate a wave function for your circuit then open the Function Generator tool from the NI ELVIS Instrument Launcher, set the parameters of … WebThe NI ELVIS II function generator is the transmitter and a high-gain op amp is the receiver. The message to be sent is formulated using the NI ELVIS II arbitrary waveform …

WebNov 25, 2024 · Measuring output into 35 Ohm load shows that 7V p-p giving 100mA peak current is achievable. i.e. +100mA when sine is at peak of +3.5V, 0mA when sine is at 0V, -100mA when sine is at -3.5V. If you mean RMS current, then 90mA RMS is the maximum possible on my GW AFG-2105 at 5kHz and 7Vpp. (approx 25 Ohm load) WebMay 4, 2024 · 05-04-2024 03:35 PM. I am trying to use the NI Elvis III toolkit within LabVIEW 2024 to control the pattern generator onboard the Elvis. I need to use the …

WebMay 4, 2024 · 05-04-2024 03:35 PM. I am trying to use the NI Elvis III toolkit within LabVIEW 2024 to control the pattern generator onboard the Elvis. I need to use the pattern generator to create a pulse output, but have been unable to get it to run correctly. Attached is my VI that I made to generate a PWM signal with what should be an 80% duty cycle at ... WebHz sine wave on the ELVIS Function Generator. Apply this signal to V. Mensure the input signal Vom using the x10 probe. The BNC-to-Grabber cable has too much capacitance and will often cause it to oscillate. Measure the peak-to-peak voltage at V. with one scope channel and measure the peak-to-peak voltage at Vin (NOT at V.) with the other channel.

WebThe NI Engineering Laboratory Virtual Instrumentation Suite (NI ELVIS) is a modular engineering educational laboratory device developed specifically for academia. With its …

WebSep 1, 2016 · NI ELVIS II Power Supply, Function Generator, Digital Multimeter Support Version 1.2.0.1 (593 KB) by MathWorks Classroom Resources Team MATLAB library … flink kafka sql connectorWebAug 12, 2011 · If you are using the NI ELVIS’ function generator as your waveform, follow the steps below to start the waveform. 1) Open the NI ELVISms Instrument Launcher by going to Start>> All Programs>> National Instruments>> NI ELVISmx Instrument Launcher for NI ELVIS and NI myDAQ>> NI ELVIS Instrument Launcher. 2) Click on the icon … greater hartford ct areaWebElvis Function Generator Tutorial 1. Turn on the NI-ELVIS II. 2. Launch NI ELVISmx Instrument Launcher. 3. Make sure that power is on the NI-ELVIS II. Click on FGEN. 4. Set the Amplitude to 0, Select FGEN BNC for Signal Route and click Run. 5. Plug in the headphones with 1/8 to RCA and RCA to BNC adapter into the FGEN BNC on Elvis flink kafka consumer groupWebFeb 12, 2024 · X. You're signed in! About the streaming player: Songs play if you keep the player window open. The music stops if you close the window. To keep the music playing … flink kafkasource scalaWebfunction generator – SYNC OUT (Output): 5V TTL signal synchronized to the FGEN signal. This signal is most used as a trigger signal for the oscilloscope (see feature 4 in Table 1). Oscilloscope (Scope) Connectors (Input) – CH A ±: The input for channel A of the oscilloscope (not applicable in NI ELVIS flink keyselectorWebMar 4, 2024 · Demonstration of using the NI ELVIS II tools (function generator, oscilloscope, dynamic signal analyzer, and Bode analyzer) to evaluate a simple passive … flink keyby deprecatedWebFigure 3: explanation of amplitude modulation in ELVIS function generator ¶ We can produce this signal with the arbitrary waveform generator (ARB). We can set a gain of 2 in ARB settings (not visible on the illustration), meaning the amplitude will become 4V at the output of the ARB, which is then connected to the AM input of the FGEN. greater hartford internal medicine